126 research outputs found
Combined Thermo-Hydraulic Analysis of a Cryogenic Jet
A cryogenic jet is a phenomenon encountered in different fields like some technological processes and cryosurgery. It may also be a result of cryogenic equipment rupture or a cryogen discharge from the cryostats following resistive transition in superconducting magnets. Heat exchange between a cold jet and a warm steel element (e.g. a buffer tank wall or a transfer line vacuum vessel wall) may result in an excessive localisation of thermal strains and stresses. The objective of the analysis is to get a combined (analytical and experimental) one-dimensional model of a cryogenic jet that will enable estimation of heat transfer intensity between the jet and steel plate with a suitable accuracy for engineering applications. The jet diameter can only be determined experimentally. The mean velocity profile can be calculated from the fact that the total flux of momentum along the jet axis is conserved. The proposed model allows deriving the jet crown area with respect to the distance from the vent and the mean velocity profile along the jet axis. A simple formula to assess convective heat exchange between the jet and a solid obstacle has been proposed and experimentally verified
Thermo-mechanical Analysis of Cold Helium Injection into Gas Storage Tanks made of Carbon Steel Following Resistive Transition of the LHC Magnets
A resistive transition (quench) of the LHC sector magnets will be followed by cold helium venting to a quench buffer volume of 2000 m3 at ambient temperature. The volume will be composed of eight medi um-pressure (2 MPa) gas storage tanks made of carbon steel, which constrains the temperature of the wall to be higher than -50oC (223 K). The aim of the analysis is the assessment of a possible spot c ooling intensity and thermo-mechanical stresses in the tank wall following helium injection
Helium Discharge and Dispersion In the LHC Accelerator Tunnel in Case of Cryogenic Failure
The Large Hadron Collider (LHC), presently under construction at CERN, will contain about 100 tonnes of helium, mostly located in the underground tunnel and caverns [1]. Potential failure modes of the accelerator, which may be followed by helium discharge to the tunnel, have been identified and the corresponding helium flows calculated. The paper presents the analysis of the helium discharge in the worst case of conditions, as well as the corresponding helium dispersion along the tunnel. The variation of oxygen concentration has been calculated and the oxygen deficiency hazard (ODH) analysed. The preventive means of protection, namely location and sizing of safety valves are also discussed
An Experimental Study of Cold Helium Dispersion in Air
The Large Hadron Collider (LHC) presently under construction at CERN, will contain about 100 tons of helium mostly located in the underground tunnel and in caverns. Potential failure modes of the accelerator, which may be followed by helium discharge to the tunnel, have been identified and the corresponding helium flows calculated. To verify the analytical calculations of helium dispersion in the tunnel, a dedicated test set-up has been built. It represents a section of the LHC tunnel at a scale 1:13 and is equipped with a controllable helium relief system enabling the simulation of different scenarios of the LHC cryogenic system failures. Corresponding patterns of cold helium dispersion in air have been observed and analysed with respect to oxygen deficiency hazard. We report on the test set-up and the measurement results, which have been scaled to real LHC conditions
Experimental Simulation of Helium Discharge into the LHC Tunnel
The LHC cryogenic system contains about 100 tons of liquid helium. The highest amount of helium is located in the magnet cold mass (about 58 tons @ 1.9 K, 0.13 MPa), in the QRL supply header C (about 26 tons @ 4.6 K, 0.36 MPa) and in the ring line (about 0.7 tons 290 K, 2 MPa). The rupture of header C is one of the failures leading to the worst scenario of helium discharge into the tunnel. To investigate the consequences of this failure an experiment has been performed. This paper presents the layout of the test set-up and compares the experimental results with calculated data
Optimisation of Multilayer Insulation: an Engineering Approach
A mathematical model has been developed to describe the heat flux through multilayer insulation (MLI). The total heat flux between the layers is the result of three distinct heat transfer modes: radiation, residual gas conduction and solid spacer conduction. The model describes the MLI behaviour considering a layer-to-layer approach and is based on an electrical analogy, in which the three heat transfer modes are treated as parallel thermal impedances. The values of each of the transfer mode vary from layer to layer, although the total heat flux remains constant across the whole MLI blanket. The model enables the optimisation of the insulation with regard to different MLI parameters, such as residual gas pressure, number of layers and boundary temperatures. The model has been tested with experimental measurements carried out at CERN and the results revealed to be in a good agreement, especially for insulation vacuum between 10-5 Pa and 10-3 Pa
Experimental and Mathematical Analysis of Multilayer Insulation below 80 K
The Large Hadron Collider [1], presently under construction at CERN, will make an extensive use of multilayer insulation system (MLI). The total surface to be insulated will be of about 80000 m2. A mathematical model has been developed to describe the heat flux through MLI from 80 K to 4.2 K. The total heat flux between the layers is the result of three distinct heat transfer modes: radiation, residual gas conduction and solid conduction. The mathematical model enables prediction of MLI behavior with regard to different MLI parameters, such as gas insulation pressure, number of layers and boundary temperatures. The calculated values have been compared to the experimental measurements carried out at CERN. Theoretical and experimental results revealed to be in good agreement, especially for insulation vacuum between 10-5 Pa and 10-3 Pa
Efficient Transformers with Dynamic Token Pooling
Transformers achieve unrivalled performance in modelling language, but remain
inefficient in terms of memory and time complexity. A possible remedy is to
reduce the sequence length in the intermediate layers by pooling fixed-length
segments of tokens. Nevertheless, natural units of meaning, such as words or
phrases, display varying sizes. To address this mismatch, we equip language
models with a dynamic-pooling mechanism, which predicts segment boundaries in
an autoregressive fashion. We compare several methods to infer boundaries,
including end-to-end learning through stochastic re-parameterisation,
supervised learning (based on segmentations from subword tokenizers or spikes
in conditional entropy), as well as linguistically motivated boundaries. We
perform character-level evaluation on texts from multiple datasets and
morphologically diverse languages. The results demonstrate that dynamic
pooling, which jointly segments and models language, is both faster and more
accurate than vanilla Transformers and fixed-length pooling within the same
computational budget
Thermohydraulics of Quenches and Helium Recovery in the LHC Magnet Strings
In preparation for the Large Hadron Collider project, a 42.5 m-long prototype superconducting magnet string, representing a half-cell of the machine lattice, has been built and operated. A series of tests was performed to assess the thermohydraulics of resistive transitions (quenches) of the superconducting magnets. These measurements provide the necessary foundation for describing the observed evolution of the helium in the cold mass and formulating a mathematical model based on energy conservation. The evolution of helium after a quench simulated with the model reproduces the observations. We then extend the simulations to a full LHC cell, and finally analyse the recovery of helium discharged from the cold mass
Oxygen Deficiency Hazard (ODH) Monitoring System in the LHC Tunnel
The Large Hadron Collider (LHC) presently under construction at CERN, will contain about 100 tons of helium mostly located in equipment in the underground tunnel and in caverns. Potential failure modes of the accelerator, which may be followed by helium discharge to the tunnel, have been identified and the corresponding helium flows calculated [1, 2, 3]. In case of helium discharge in the tunnel causing oxygen deficiency, personnel working in the tunnel shall be warned and evacuate safely. This paper describes oxygen deficiency monitoring system based on the parameter of limited visibility due to the LHC tunnel curvature and acceptable delay time between the failure and the system activation
- âŠ